Adjust the potentiometer clockwise to increase the detection range.
You can set the sensor to detect only "forward" motion (people walking toward the door) to save energy by not opening for people walking away. Infrared (Safety) Adjustments prosecure opti combi manual english
To meet or DIN 18650 standards, the infrared safety curtain must be tested daily. The Prosecure Opti Combi features a self-monitoring "Test Input" that the door controller uses to verify the sensor is functional before every closing cycle. Adjust the potentiometer clockwise to increase the detection
The Prosecure Opti Combi is designed for high-pedestrian areas. It utilizes radar technology for activation and Active Infrared for safety. 1. Mounting and Installation Maximum Height: Typically 3 meters (approx. 9.8 feet). The Prosecure Opti Combi features a self-monitoring "Test
Use a flathead screwdriver to gently pop the side tabs to access the internal buttons. 2. Wiring Connections
Prosecure Opti Combi sensors are sophisticated combined radar and infrared systems used primarily for automatic sliding doors. They handle both motion detection (to open the door) and presence detection (to prevent the door from closing on someone). 🛠️ Prosecure Opti Combi: Quick Setup Guide