To ensure the longevity of your INVT drive, the installation environment must meet specific criteria:

P0.01 (Source of Run Command): 0 for Keypad, 1 for Terminal Control, 2 for Communication.P0.03 (Max Output Frequency): Usually set to 50.00Hz or 60.00Hz depending on your motor.P0.11 (Acceleration Time): Time in seconds to reach max frequency.P0.12 (Deceleration Time): Time in seconds to reach a full stop.P2.01 (Motor Rated Power): Set to 0.75kW.P2.02 (Motor Rated Voltage): Set to 220V.P2.05 (Motor Rated Current): Set according to your motor's nameplate (typically around 3.5A–4.0A). Troubleshooting Common Fault Codes

S1 to S4: Multi-function digital inputs (forward, reverse, multi-speed).+10V, AI1, GND: External potentiometer or 0–10V analog input for frequency control.485+, 485-: Standard RS485 communication ports for PLC integration.RO1A, RO1C: Relay output for fault signaling or status monitoring. Basic Programming and Parameter Settings

By following this manual guide, you can ensure a stable and efficient setup for your INVT CHE100-0R7G-S2. For complex automation logic or Modbus communication setups, refer to the full manufacturer PDF for advanced parameter mapping.

Model Number: CHE100-0R7G-S2Rated Power: 0.75 kW (1.0 HP)Input Voltage: Single-phase 220V AC (±15%)Output Voltage: Three-phase 0–220V ACRated Current: 4.0AControl Mode: Sensorless Vector Control (SVC) or V/f ControlProtection Rating: IP20 Installation and Environment Guidelines

Proper wiring is the most critical step in preventing drive failure or electrical hazards. Main Circuit Terminals

Before beginning installation, verify that your hardware matches the following electrical ratings: